Estrogens, Total Serum by LC/MS-MS

CPT: 82672

Specimen Requirements


Specimen

Serum (preferred), or plasma, frozen

Volume

3 mL

Minimum Volume

1 mL (Note: This volume does not allow for repeat testing.)

Container

Gel-barrier tube, lavender top (EDTA) tube, or tube green-top heparin tube

Collection

Serum or plasma must be separated from cells within 45 minutes of venipuncture. Send serum or plasma in a plastic transfer tube.

Storage Instructions

Freeze

Stability Requirements

Temperature Period Room Temperature 7 days Refrigerated 7 days Frozen 2 years

Causes for Rejection

Gross hemolysis, gross lipemia, incorrect specimen type

Test Details


Methodology

Liquid chromotography tandem mass spectrometry (LC/MS/MS)